Controller peripheral: Difference between revisions
Jump to navigation
Jump to search
(Created page with "The controller acts as a main peripheral device on the Maple Bus. == Controller == The "get condition" command (0x09) with controller function code is used to...") |
mNo edit summary |
||
(One intermediate revision by the same user not shown) | |||
Line 13: | Line 13: | ||
! Byte 0 (LSB) !! Byte 1 !! Byte 2 !! Byte 3 (MSB) | ! Byte 0 (LSB) !! Byte 1 !! Byte 2 !! Byte 3 (MSB) | ||
|- | |- | ||
| Left analog trigger 0 to 255<br>0: fully released<br>255: fully pressed || Right analog trigger 0 to 255<br>0: fully released<br>255: fully pressed || Button bits<br>0x01: Z<br>0x02: Y<br>0x04: X || Button bits<br>0x01: C<br>0x02: B<br>0x04: A<br>0x08: Start<br>0x10: Up<br>0x20: Down<br>0x40: Left<br>0x80: Right | | Left analog trigger 0 to 255<br>0: fully released<br>255: fully pressed || Right analog trigger 0 to 255<br>0: fully released<br>255: fully pressed || Button bits<br>0x01: Z<br>0x02: Y<br>0x04: X<br>0x08: D<br>0x10: Up-b<br>0x20: down-b<br>0x40: left-b<br>0x80: right-b || Button bits<br>0x01: C<br>0x02: B<br>0x04: A<br>0x08: Start<br>0x10: Up<br>0x20: Down<br>0x40: Left<br>0x80: Right | ||
|} | |} | ||
Line 22: | Line 22: | ||
! Byte 0 (LSB) !! Byte 1 !! Byte 2 !! Byte 3 (MSB) | ! Byte 0 (LSB) !! Byte 1 !! Byte 2 !! Byte 3 (MSB) | ||
|- | |- | ||
| Right analog stick up/down<br> | | Right analog stick up/down<br>0: fully up<br>128: center<br>255: fully down || Right analog stick left/right<br>0: fully left<br>128: center<br>255: fully right || Left analog up/down<br>0: fully up<br>128: center<br>255: fully down || Left analog left/right<br>0: fully left<br>128: center<br>255: fully right | ||
|} | |} |
Latest revision as of 19:08, 1 January 2023
The controller acts as a main peripheral device on the Maple Bus.
Controller
The "get condition" command (0x09) with controller function code is used to poll controller state. A "data transfer" command (0x08) is returned with controller function code word plus 2 words of data. The returned data must be parsed differently depending on the function definition for the controller. The below sections show how to parse data for a standard controller.
First Data Transfer Word
All button bits are 0 when pressed and 1 when released.
Byte 0 (LSB) | Byte 1 | Byte 2 | Byte 3 (MSB) |
---|---|---|---|
Left analog trigger 0 to 255 0: fully released 255: fully pressed |
Right analog trigger 0 to 255 0: fully released 255: fully pressed |
Button bits 0x01: Z 0x02: Y 0x04: X 0x08: D 0x10: Up-b 0x20: down-b 0x40: left-b 0x80: right-b |
Button bits 0x01: C 0x02: B 0x04: A 0x08: Start 0x10: Up 0x20: Down 0x40: Left 0x80: Right |
Second Data Transfer Word
Byte 0 (LSB) | Byte 1 | Byte 2 | Byte 3 (MSB) |
---|---|---|---|
Right analog stick up/down 0: fully up 128: center 255: fully down |
Right analog stick left/right 0: fully left 128: center 255: fully right |
Left analog up/down 0: fully up 128: center 255: fully down |
Left analog left/right 0: fully left 128: center 255: fully right |